40 research outputs found

    Carotid Ultrasound Boundary Study (CUBS): An Open Multicenter Analysis of Computerized Intima–Media Thickness Measurement Systems and Their Clinical Impact

    Get PDF
    [Abstract] Common carotid intima–media thickness (CIMT) is a commonly used marker for atherosclerosis and is often computed in carotid ultrasound images. An analysis of different computerized techniques for CIMT measurement and their clinical impacts on the same patient data set is lacking. Here we compared and assessed five computerized CIMT algorithms against three expert analysts’ manual measurements on a data set of 1088 patients from two centers. Inter- and intra-observer variability was assessed, and the computerized CIMT values were compared with those manually obtained. The CIMT measurements were used to assess the correlation with clinical parameters, cardiovascular event prediction through a generalized linear model and the Kaplan–Meier hazard ratio. CIMT measurements obtained with a skilled analyst's segmentation and the computerized segmentation were comparable in statistical analyses, suggesting they can be used interchangeably for CIMT quantification and clinical outcome investigation. To facilitate future studies, the entire data set used is made publicly available for the community at http://dx.doi.org/10.17632/fpv535fss7.

    Enteral versus intravenous approach for the sedation of critically ill patients: a randomized and controlled trial

    Get PDF
    Background. ICU patients must be kept conscious, calm, and cooperative even during the critical phases of illness. Enteral administration of sedative drugs might avoid oversedation, and would be as adequate as intravenous for awake patients, with fewer side effects and lower costs. This study compares two sedation strategies, in order to early reach and maintain the light sedation target. Methods. Multicenter, single-blind randomized and controlled trial carried out in 12 Italian ICUs, involving patients with expected mechanical ventilation duration >72 hours at ICU admission and predicted mortality >12% (Simplified Acute Physiology Score II >32 points) during the first 24 ICU hours. Patients were randomly assigned to receive intravenous (midazolam, propofol) or enteral (hydroxyzine, lorazepam, and melatonin) sedation. Primary outcome: percentage of work shifts with an observed Richmond Agitation-Sedation Scale (RASS) = target RASS \ub1 1. Secondary outcomes: protocol feasibility, delirium- and coma-free days, costs of drugs, length of ICU and hospital stay, ICU, hospital, and one-year mortality. Results. 348 patients were enrolled. There were no differences in the primary outcome: enteral 89.8 [74.1-100], intravenous 94.4 [78-100]%, p=0.20. Enteral-treated patients had more protocol violations: 81 (46.6%) vs 7 (4.2%), p<0.01, more self-extubations: 4 (2.4%) vs 14 (8.1%), p=0.03, a lighter sedative target (RASS = 0): 93 [71-100] vs 83 [61-100]%, p<0.01, and lower total costs for drugs: 2.39 [0.75- 9.78] vs 4.15 [1.20 -20.19] \u20ac/day with mechanical ventilation (p=0.01). Conclusions. Although enteral sedation of critically ill patients is cheaper and permits a lighter sedation target, it is not superior to intravenous sedation for reaching the RASS target. Trial registration. ClinicalTrials.gov, Clinical Trial #NCT01360346, registered 25 March 2011, https://clinicaltrials.gov/ct2/show/NCT01360346. Registered on 25 March 2011

    Understanding Factors Associated With Psychomotor Subtypes of Delirium in Older Inpatients With Dementia

    Get PDF

    PREVENZIONE PER OBESITÀ E DISTURBI DEL COMPORTAMENTO ALIMENTARE: ELABORAZIONE DI UN PROGETTO DI EDUCAZIONE ALIMENTARE PER LA SCUOLA PRIMARIA

    No full text
    La tesi descrive un'esperienza di prevenzione dell'Obesità e dei Disturbi Alimentari, nata dalla collaborazione tra il Dipartimento di Farmacia e l'Istituto scolastico, Scuola Elementare F. Gasparini Musicista del comune di Camaiore provincia di Lucca. L'obiettivo del lavoro consiste nell'elaborazione e nella realizzazione di un progetto di educazione alimentare efficace, per sensibilizzare rispetto al problema dell'eccesso ponderale infantile, fornire corrette informazioni sul valore nutrizionale degli alimenti e sulla corretta ripartizione degli apporti energetici nell'arco della giornata, e per fornire delle linee guida per un'alimentazione sana, varia ed equilibrata. La tesi, a partire dall'epidemiologia e dall'eziopatogenesi della obesità e dal ruolo dell'eccesso ponderale come fattore di rischio per l'insorgenza di patologie in età evolutiva ed in età adulta, analizza il ruolo della prevenzione, anche attraverso lo studio delle misure di intervento che sono già state messe in atto come azioni. Il progetto viene sviluppato seguendo un piano di intervento a più livelli che, tramite lezioni frontali didattiche, coinvolge sia i bambini che gli adulti di riferimento, genitori ed insegnanti. Inoltre, per coinvolgere maggiormente gli alunni della scuola al programma di educazione alimentare sono stati realizzati dei laboratori sensoriali. Questi laboratori hanno permesso ai bambini di approcciarsi al tema dell'alimentazione come risposta al fabbisogno energetico, ma anche per i suoi significati edonici ed emotivi attraverso l'utilizzo dei sensi (vista, tatto, olfatto e gusto). Per verificare l'efficacia dell'intervento sono stati somministrati agli alunni dei questionari validati che indagavano abitudini alimentari, attività fisica svolta e comportamenti sedentari (TV e videogiochi). La partecipazione al progetto è risultata molto favorevole da parte sia della scuola che dei ragazzi, e il lavoro svolto può rappresentare un punto di partenza per la realizzazione di un piano di intervento di prevenzione più ampio, coinvolgendo le famiglie quali primo esempio per i bambini per seguire un corretto stile di vita basato su una sana alimentazione e una regolare attività fisica

    Development of an innovative portable and easy-to-use ultrasound-based system for carotid biomarkers assessment

    No full text
    The overall burden of cardiovascular disease (CVD) is increasing worldwide and the capability of identifying high-risk individuals using reliable and feasible tools is a primary step in tackling the global healthcare challenge of CVD prevention. Most of the recommended CVD risk prediction scores are solely dependent upon conventional risk factors (such as smoking, obesity, hypercholesterolemia, and hypertension) but it is widely accepted by the scientific community that the description of the cardiovascular status of a person, based only on classic risk factors, is not enough in terms of clinical effectiveness nor in terms of cost to the National Health System. The ability to identify a "vulnerable" subject, through an effective screening model, can be increased by the introduction of innovative biomarkers, such as those measurable on biomedical signals and images, which are able to detect the presence of vascular damage at the sub-clinical and asymptomatic stage long before the onset of disease. A leading cause for CVD is atherosclerosis. In the presence of an unopposed and excessive amount of fatty streak formation, the artery undergoes progressive atherosclerotic changes starting from endothelial dysfunction, and gradually remodelling the artery with wall thickening and arterial stiffening, up to vessel wall damage resulting in complicated stenotic lesion. Some of these changes, asymptomatic in the initial stages of atherosclerosis, can be non-invasively estimated by imaging as early biomarkers of atherosclerosis. In the last years, significant effort has been made to develop reliable and non-invasive systems with the aim of establishing preventative strategies, methods of detection and risk-stratification, and therapeutic interventions by using image-based biomarkers. Researchers and clinicians rely heavily on the use of imaging modalities to quantify the burden of atherosclerosis in arteries including the aorta, carotid arteries, coronary arteries, peripheral vasculature, and microvasculature. Atherosclerosis imaging techniques include modalities with advantages such as high resolution and real time, but which conversely are invasive, time-consuming, and expensive, and expose the patients to ionizing radiations, such as angiography and computed tomography. Ultrasound imaging represents an accessible, safe, and low-cost technique that can be used for atherosclerosis imaging and assessment of the cardiovascular risk. Recently, robust automated tools were developed, using various engineering methods, for quantification of wall thickness and carotid plaque measurements, the so-called image phenotypes, from B-mode carotid ultrasound. Among carotid biomarkers of vascular aging, the most extensively studied were carotid Intima-Media Thickness (IMT) and arterial elasticity. Carotid IMT has been considered for a long time a surrogate marker for atherosclerosis and predictor of future vascular events that can be estimated by ultrasound imaging. Similarly, arterial stiffness represents an alteration in vascular function and structure, it is evident from the earliest stages of vascular aging and it has been included in the guidelines for the management of hypertension by the European Society of Hypertension and Cardiology as an important component for the overall cardiovascular risk assessment. The increase of arterial stiffness is measurable in different parts of the arterial tree and great attention has been placed on the local estimation at the carotid site by ultrasound imaging. Unfortunately, the currently available approach for measuring these biomarkers, besides highly qualified and experienced operators, requires an awkward and bulky system. For the assessment of IMT, carotid diameter (D) and its distension (ΔD), three devices are often required: a standard ultrasound equipment for images acquisition, an automatic software able to provide the biomarkers estimation installed on a laptop, and a video converter connecting the two. Hence, the general objective of this project is to make carotid biomarkers of atherosclerosis more easily accessible. In order to obtain a reliable and useful stratification of the cardiovascular risk, it is necessary to spread these innovative tools from the research setting to clinical practice and to provide a system configuration to be used also in out-of-office settings. This research project consists in the development and validation of a device, based on an ultrasound data processing, for non-invasive assessment of carotid IMT and elasticity, which is portable, easy-to-use, low-cost, and reliable, able to provide a concrete technological solution for the implementation of a new screening model encouraged by the scientific community but still too far from reality. This project intends to implement an approach, aimed at the early prevention of cardiovascular disease among the population, based on the evaluation of ultrasound carotid biomarkers for detecting the presence of pre-clinic atherosclerotic disease and monitor vascular changes due to disease/treatment. Specifically, a non-invasive, easy-to-use, and portable ultrasound system that can be used in screening campaigns in non-hospital facilities such as outpatient clinics, out-of-office settings, squares, etc. for the measurement of carotid IMT and stiffness has been designed and developed. This innovative system consists of an embedded ultrasound imaging system and a stand-alone software for the evaluation of the biomarkers, aiming to obtain an innovative, technically simpler, easier-to-use, and portable system to assess cardiovascular risk in a non-hospital facility. The new generation of USB ultrasound probe has been deeply analysed for designing, developing, and then validating an innovative system for carotid biomarkers assessment. The innovative system, which is made up only by a light ultrasound probe connected via USB to a laptop running the software for the images analysis, overcomes the limitations of bulkiness, awkwardness and high cost that instead characterize the commonly used equipment. With this new configuration, the probe is directly attached to the computer, and it is no more necessary to use a video converter for retrieving the images coming from the ultrasound machine to be sent to the software for the processing because. The design and development of this innovative system, which consists of the SP-L01 Linear Array Probe by Interson and the software Carotid Studio by Quipu Srl, included, in a first step, the integration between the hardware and the software. Regarding the hardware component, an in-depth research to determine which devices were available on the market has been carried out, and among them, a comparison analysis in terms of technical specifications, integration, available source code, ultrasound image quality, usable probes, cost, and regulatory requirements (for example FDA approval and/or CE mark) was performed. Regarding the software, Carotid Studio is a software for the estimation of vascular parameters by ultrasound imaging based on a well validated contour tracking algorithm. This software medical device has achieved the CE mark according to the European Directive 93/42/EEC and subsequent amendments and supplements for medical devices. The software measures the diameter and the intima-media thickness in B-mode ultrasound image sequences of the longitudinal section of the carotid artery. The measurement is obtained automatically and in real-time, thanks to a well validated method that is based on a special contour tracking algorithm. The performance of the measurements, when performed with this kind of algorithm, depends not only on the robustness of the adopted algorithm, but also on the quality of the analysed scan, which is affected by device settings [11,12]. Therefore, within this work it was investigated how different image settings may affect carotid biomarkers estimation performed by the Carotid Studio. In fact, standardization of image settings for semi-automatic measure¬ments is required and it is particularly important especially when the measured parameters are widely used for the calculation of risk, the establishment of reference values and for the prediction of an outcome. After having identified the software and the best device for the system (i.e., the hardware), the integration between the ultrasound probe and the software has been developed. This task has required the design and implementation of two software modules: a video interface module that should retrieve the images from the ultrasound system and send them to the software video player, and a control module that should accept commands from the user interface for controlling and adjusting the parameters of the ultrasound system (for example image depth, gain, focus depth, etc.). Both software modules were developed in C++ language by integrating the Software Development Kit (SDK) with the Qt platform (https://www.qt.io/). The Application Programming Interface (API) was integrated and used to communicate with the probe and to control and adjust the probe itself. The software modules were finally compiled for Windows operating system environment. Then, the integrated system has been technically validated in terms of reproducibility of the measurement by an intra-operator inter-session study, with reproducibility expressed as coefficient of variation, and data were compared with the previously published papers regarding Carotid Studio performance. The system was also validated by in lab agreement with the reference technique, in which measurements obtained with the new system have been compared with those based on standard ultrasound equipment, and the agreement between the two approaches was evaluated by Bland-Altman plots. Measurements of carotid D, IMT e ΔD were successfully analysed from all the sequences of images acquired with both the standard solution and the portable approach in twelve healthy volunteers, revealing good reproducibility of the measurements and agreement with state-of-the-art technique, with reference to values reported in the literature. The integrated system was last validated in terms of usability, according to IEC 62336 “Medical devices — Part 1: Application of usability engineering to medical devices”, by collecting usability information thanks to questionnaires distributed to physicians testing the system, to ensure safety and confirm the improvement of the new approach. The usability results evidenced that the new approach is overall very satisfying as regard to its general quality, its easiness for the users that performed all the representative tasks, and its potential usage in clinical practice even though the need for reducing the time required to complete the configuration and for improving the suitability of the graphical user interface emerged. The design and development of the integrated system has been managed also taking into consideration the regulatory framework of the medical devices. In particular, the new European Regulation (EU) 2017/745 on Medical Devices was published in May 2017 and took effect from 26 May 2021. It has introduced some aspects on how medical devices are investigated, approved, and monitored and affect their daily clinical practice of healthcare professionals in Europe. Medical devices definition includes software, and the new Regulation, for the first time, provides an entirely dedicated article to the rules for its classification (Par. 6.3, Rule 11). In this work, two class IIa medical devices have been assembled and they have been validated both from a technical and usability points of view. The risk management process has been considered during all the phases of the design and development according to the reference standards (i.e., ISO 14971 and IEC 62304) for this field of application. In addition, during this research period, some key points arising from the regulatory context, such as the traceability of the medical device and the quality management system of the manufacturer, have been examined in depth. These preliminary results pave the way for a faster, simple evaluation of relevant carotid parameters, describing comprehensively different aspects of the vascular aging process and allowing multiparametric, accurate, assessment of individual CV risk. Furthermore, the new smart system will make it simpler to track the effect of targeted non-pharmacological and pharmacological treatments through repeated measures, thus accelerating the clinical development of new cardiovascular drugs. In addition, the presented system is specifically designed to allow an easy assessment of carotid biomarkers in the largest possible population, including those considered at low or intermediate cardiovascular risk. The latter is the subset in which the measure of vascular aging has the highest predictive value when added to conventional risk scores. Early reclassification of patients as high risk based on vascular aging assessment is a crucial preliminary step to implement simple actions such as change in lifestyle, who could have a significant impact on mitigating the risk of developing overt disease. In order to reach this population at low-to-intermediate risk, preventive campaigns must take place outside the hospital, such as in pharmacies, squares, shopping mall or wellness centre. This approach is aimed of increasing in the general population the awareness of their vascular age and cardiovascular risk, thus promoting a healthier lifestyle and appropriate treatments

    Play and age: the effect of early social deprivation on play modality in chimpanzees (Pan troglodytes)

    No full text
    In this project, we investigated the playful activity in four groups of chimpanzees (Pan troglodytes) living in semi-wild conditions. We found that play is modulated by intrinsic features of the players and social variables. Indeed, the frequency of solitary was higher for immature subjects compared to adult individuals, but for social play it was generally lower in more tolerant groups compared to less tolerant ones. We also found that being orphan and living in an impoverished social environment was correlated with a reduction of the motivation to play, resulting in lower frequency of dyadic social play compared to juveniles living in other groups. Moreover, the outcome of the sessions was more frequently negative if an older individual was the initiator, but this was not connected with the restricted capabilities of orphans because they showed similar Roughness Index (RI) to other juveniles and the lowest proportion of badly ended bouts. Conversely, playful bouts lasted longer when they involved mother-reared juveniles compared to sessions including orphan individuals. We found the phenomenon of facial mimicry in the studied chimpanzees, and it was tendentially lower when individuals of different sexes were involved in a playful bout compared to play sessions including same-sex individuals, but again no differences were observed between orphans and mother-reared subjects

    Experimental campaign on the sensor package for a smart capture tool

    No full text
    In-Orbit-Assembly missions open several opportunities such as the construction of large antennas or other assets in space. To this aim, space robots have been identified as one of the most promising systems to perform assembly tasks. They requie enabling technologies like interfaces, proximity sensors, and actuators in order to handle and move the building blocks (Elementary Assembly Units, EAUs) of the larger structure. Typically, the sensors and the capture tool of the robotic arm are managed by the main computer of the space robot and are specific for a determined architecture of the manipulator. This work considers a new type of capture tool which is autonomous from the space robot and able to manage the EAU from the capture to the moving and assembly in the structure. To this aim, the proposed system (SMArt Capture Kit, SMACK) is equipped with three types of sensors and a gripper-like capture tool. They are managed by a decentralised computer that executes estimation and guidance algorithms in order to drive a robotic arm to capture and assembly the EAU. The paper will focus on the description of the sensors and on the estimation algorithm. It has been described and tested in order to verify its performances

    New training methods based on mixed reality for interventional ultrasound: Design and validation

    No full text
    Currently the learning model for ultrasound imaging diagnosis and intervention follows a traditional approach based on learning by doing but this model exposes the patient to the whole learning curve of the novice. In order to enable training in a safe environment without compromising patient's health we have developed and demonstrated face, content and construct validity of a hybrid simulator for ultrasound-guided biopsy. This hybrid simulator is able to provide a support to acquire skills in term of 3D perception and hand-eye coordination thanks to a mixed reality visualization that allows accurate and easy planning of probe position/orientation and needle trajectory to reach the target
    corecore